Description
FEATURESÂ
ADVANCED FUNCTIONALITIES
Philips Gs20 Patient Monitor Provides Real-Time Data On Cardiac And Respiratory Conditions In Order To Fit Different Clinical Settings As Well As Specific Monitoring Parameters Such As Philips St.) Ar 3-And5-Lead Ecg/ Respiration, Nbp 2 Temperatures And Philips Spo2/Pr St And Arrhythmia Monitoring, It Also Offers Options For 2-Channel Intrusive Blood Pressure And Microstream Etc02 Monitoring
EASE OF USE
Gs20 Patient Monitor Has A 10.4-Inch Color Display With Flexible Display Modes Such As Large Number Display Minitrend, Oxycrg, And The Neight Adjustment Function Of The Auto Waveform Channel To Fit Different Clinical Settings For Maximum Ease Of Use Intuitive Menus, Fixed Key Access Bright Color Screen, And Optional Touch Screen Nav All Been Designed
COMPACT AND COST-EFFECTIVE
The Philips Goldway Gs20 Patient Monitor, Designed In Compliance With Philips Exacting Quality Standards, Offers Market-Proven Critical Parameters In A Lightweight Cost-Effective Display To Produce Precise Measurement Results On Your Tight Budget.
WORK WITH EFFICIA CONSUMABLES
The Philips Gs20 Patient Monitor Is Designed To Be Compatible With Consumables From Philips Efficia, Which Are Also Used On Patient Monitors From The Philips Emicis Cm Series, To Reduce Your Total Cost Of Ownership By Sharing Consumables From Philips Across Various Care Settings
SPO2Â
- Measurement Range : 0- 100%
- Accuracy :Â 70 % – 100 % , Depends On Sensor , 0 -69 % , Unspecified
- Waveform Speed :Â 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
- Pulse Rate Range :Â 30 bpm -300 bpm
- Pulse Rate Accuracy : 土2 bpm or 土2%, Whichever is Greater
- Perfusion Index :Â Yes
RESPIRATION (RESP)
- Measurement Method :Â Thoracic Impedance
- Measurement Range :Â 0 rpm – 150 rpm
- Accuracy : 0 rpm – 120 rpm : 土 1 rpm ; 121 rpm – 150 rpm: 土2 rpm
- Waveform Speed :Â 6.25 mm/s, 12.5 mm/s, 25 mm/s , 50 mm/s Accuracy Undefined
- Gain Selection : x ½ , x 1, x 2
- Apnea Alarm :Â Yes , 10-60 s
- Work Mode :Â Auto Or Manual (Threshold)
- RESP Lead :Â RA-LL
TEMPERATURE (TEMP, 2- CHANNEL)
Measurement Range : 0 -50 °C (32 °F – 122 °F)
Accuracy : 土0.1 °C (土0..2 °F ) ( Without Sensor)
Resolution : 0.1 °C (0.2°F)
Units : °C / °F
Minimum Measuring Time : Attachable skin Surface Probe Less Than 10 Minutes Esophageal/Rectal Probe : Less Than 2 Minutes
-
ECG
Lead Type 3-Lead Or 5-Lead Selectable Lead Selection, 3-Lead I, II, III Lead Selection, 5-Lead I, II, III, aVR aVL, aVF. V Hr Measurement Adult/Pediatric: 15 bpm-300 bpm Neonatal 15 bpm – 300 bpm Step 1 bpm Hr Accuracy 15 bpm or ±1%, Whichever is Arrhythmia 21 calls St Measurement Range -25 mV-+2 5 mV Waveform Speed 6.25 mm/s 12.5 mm/s, 25 mm/s, Gain Selection x 1/4, x 1/2 x 1, x2, x 4, Auto Pacemaker Detection Yes -
NON-INVASIVE BLOOD PRESSURE (NIBP)
Method Automatic Oscillometic Parameters SYS/DIA/MAP/Pulse Rate Operating Mode Manual/Auto/STAT Auto Measure Intervals 3, 5, 10, 15, 30, 60, 90, 120, 240 480 Minutes Units mmHg/kPa Cuff Pressure Range , Adult/ Pediatric 0-300 mmHg (0 kPa -40.0 kPa) Cuff Pressure Range , Neonatal 0-150 mmHg (0 kPa – 20.0 kPa) Systolic Measurement Range, Adult /Pediatric Systolic Measurement 30mm rig-135 mmHg (4 0 kPa -33.9 kPa) Systolic Measurement Range, Neonatal 30 mmHg -135 mmHg (4.0kPa-18.0 kPa) Diastolic Measurement Range , Adult / Pediatric 10 mmHg -220 mmHg (1.3 kPa-29.3 kPa) Diastolic Measurement Range , Neonatal 10 mmHg -110 mmHg (1.3 kPa-14.7 kPa) Map Measurement Range , Adult / Pediatric 20 mmHg -235 mmHg (2.7 kPa-31.3 kPa) MAP Measurement Range ,Neonatal 20 mmHg -125 mmHg (2.7 kPa-16.7 kPa) Accuracy , Maximum standard Deviation 8 mmHg (1.1 kPa) Accuracy , Mean Error 土5 mmHg (土0.7 kPa) Pulse rate Range 40 bpm -240 bpm Pulse Rate Accuracy 土 5 bpm or 土5%, Whichever is Greater